<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-17 08-58-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
4.8 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 14 kHz 18118 13,2134
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,58 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 14 kHz MIN: 10 kHz % above 76 kHz: 13,2134 Acquired: 2026.09.17 8.57.44 Total samples: 18118 Equivalent time: 0:15:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,4 dBr MIN: 2,7 dBr AVE: 4,58 dBr % above 12,2 dBr: 0,0 Last value: 3,2 dBr (2026.09.17 8.57.44) 08.44 08.46 08.48 08.50 08.52 08.54 08.56 0 2 4 6 Pm [dBr]